PROMASEAL® Retrofit Collar (square base)

ADVANTAGES

  • To protect pipes up to 315mm OD
  • Tested up to 4 hrs
  • Tested with uPVC, HDPE, Raupiano, cPVC and many more
  • Can be used to protect cables and lagged copper pipes
  • Wall or floor application
  • Tested in wide variety of wall types including FR Plasterboard, Speedpanel and Hebel amongst others

Fire Resistant Collar for Plastic Pipes Penetration Seals

Square based PROMASEAL® Retrofit Collar (FC type) is multi purpose collar designed for use with concrete slabs, masonry and lightweight walls and lined ceilings.

The split type collar can be retrofitted where necessary. It is available in a range of sizes to suit plastic pipes up to 315mm outside diameter.

Note that PROMASEAL® Retrofit Collars above 150mm have a circular base.

Applications

Dimension
< #Back#

DIMENSION

Code no.   FC 40 FC 50 FC 65 FC 80 FC 100 FC 150 FC 250 FC 300
Pipe nominal diameter mm 40 50 65 80 100 150 250 300
Body H mm 43 43 43 43 53 73 120 160
D1 mm 45 58 71 85 112 162 254 318
D2 mm 77 90 103 123 150 200 316 402
Flange D3 mm 112 125 138 158 185 235 380 Ø 466 Ø
 Carton Quantity
20 20 15 10 10 5 1 2

 

Square based PROMASEAL® Retrofit Collars are manufactured under a quality management system certified in accordance with ISO 9001: 2008. The production unit has passed the site audit of ISO 14001 and all manufacturing processes are in accordance with the environmental standards of ISO 14001: 2004 and the safety standards of AS 4801: 2001.

DIMENSION

Code no.   FC 40 FC 50 FC 65 FC 80 FC 100 FC 150 FC 250 FC 300
Pipe nominal diameter mm 40 50 65 80 100 150 250 300
Body H mm 43 43 43 43 53 73 120 160
D1 mm 45 58 71 85 112 162 254 318
D2 mm 77 90 103 123 150 200 316 402
Flange D3 mm 112 125 138 158 185 235 380 Ø 466 Ø
 Carton Quantity
20 20 15 10 10 5 1 2

 

Square based PROMASEAL® Retrofit Collars are manufactured under a quality management system certified in accordance with ISO 9001: 2008. The production unit has passed the site audit of ISO 14001 and all manufacturing processes are in accordance with the environmental standards of ISO 14001: 2004 and the safety standards of AS 4801: 2001.

Approved Fixings
< #Back#

The approved fixings for use with PROMASEAL® Retrofit Collar must be all steel. Any use of fixings with plastic, zinc or other materials as part of the fixing or sleeve are not suitable and have been shown to seriously affect the performance of the fire collar. Below is a link to a document showing approved and non approved fixings. This list is not exhaustive, for approval of specific fixings not shown on the list please contact your local Promat office

Fixing information for Promat Collars

The approved fixings for use with PROMASEAL® Retrofit Collar must be all steel. Any use of fixings with plastic, zinc or other materials as part of the fixing or sleeve are not suitable and have been shown to seriously affect the performance of the fire collar. Below is a link to a document showing approved and non approved fixings. This list is not exhaustive, for approval of specific fixings not shown on the list please contact your local Promat office

Fixing information for Promat Collars

Floor Waste
< #Back#
The PROMASEAL® Retrofit Collar is not approved for and should not be used in Floor Waste Applications. Where protection of floor wastes is required, refer to the PROMASEAL® Floor Waste Retrofit Collar.
The PROMASEAL® Retrofit Collar is not approved for and should not be used in Floor Waste Applications. Where protection of floor wastes is required, refer to the PROMASEAL® Floor Waste Retrofit Collar.
Health & Safety
< #Back#

HEALTH & SAFETY

No special precautions are required. For more information please check the material safety data sheet, available upon request.

 

WASTE DISPOSAL

Handle as construction industry waste and dispose of in compliance with all local and national regulations in the appropriate and approved manner.

HEALTH & SAFETY

No special precautions are required. For more information please check the material safety data sheet, available upon request.

 

WASTE DISPOSAL

Handle as construction industry waste and dispose of in compliance with all local and national regulations in the appropriate and approved manner.

Documents
< #Back#

System Certificate

System Certificate

Installation Guide

Installation Guide

Product Datasheet

Product Datasheet

Safety Datasheet (SDS)

Safety Datasheet (SDS)

System Certificate

System Certificate

Installation Guide

Installation Guide

Product Datasheet

Product Datasheet

Safety Datasheet (SDS)

Safety Datasheet (SDS)